Drop a diffusion series anywhere, or choose an example.
Drop a diffusion series anywhere, or choose an example.
DWI Correct corrects a diffusion MRI series in this browser, as FSL eddy does: head motion, eddy-current distortion, susceptibility distortion and slices that lost signal are estimated together, and every volume is resampled once with Jacobian modulation. Each volume is registered to a prediction from the others (3dSHORE for 72 or more diffusion-weighted volumes, else a Gaussian process); slices far below their prediction are replaced by it. It runs the shoreline command line (exes/dwi/shoreline), implemented from the eddy papers without FSL code: on synthetic phantoms with known truth it had lower error than FSL eddy 6.0.7.7 in every scheme tested, and on 30 ADNI sessions its corrected images correlated 0.98-0.99 with eddy's. The susceptibility field comes from a reverse phase-encoding b0 (the SDC app's PyHySCO port), a topup _fieldcoef image or a field map in Hz. The brain mask is MindGrab's, from the mean b0. Outputs use BIDS derivative names: the corrected series with its bval, bvec and sidecar, the movement and outliers per volume, the mask and the field. Series that need more than WebAssembly's 4 GB (HCP-sized data) are refused; the native command line handles them. The example is OpenNeuro ds006676 sub-001 (CC0; Zhang et al., Human Brain Mapping 2025), a multiband 3 series of 141 volumes with a PA b0; its sidecar lacks the multiband factor, so it was added.
Images are processed locally in this browser and are never uploaded.